LaserStudio User Manual

Move, machine position and Home

The Move tab controls laser-off positioning on a qualified connection. Read Laser safety and follow the engraver manufacturer’s instructions before requesting motion.

Read Machine X and Y

Machine X/Y comes from the controller’s machine coordinate report. It can be negative. Use Optional measured bed reference to tell LaserStudio where the head is physically located, measured from the bed’s front-left. Application bed-edge checking depends on that reference.

Choose a positioning control

ControlWhat it does
Direction arrowsRequests a jog using the selected distance and speed. Diagonal arrows move both axes.
HomeRequests the controller’s homing cycle when the controller and checks allow it. Homing clears the measured bed reference.
Stop movementRequests cancellation of active positioning. Use the manufacturer’s emergency stop procedure if motion cannot be stopped safely from the app.

Check placement after homing

Home uses the controller’s homing switches and its configured axes. Review the clearance and switch checks shown by LaserStudio. Re-establish the measured bed reference before relying on it for a later placement check. See Work area and job origin.

Surfstats LaserStudio · November 2026 development build